Recall campaign · NHTSA 16V293000

Equipment

E-One Incorporated filed this campaign with NHTSA on 2016-05-12.

Recall campaignNHTSA 16V293000

Equipment

Component
Equipment
Manufacturer
E-One Incorporated
Vehicles affected
140
Reported to NHTSA
2016-05-12
Owners notified
2016-06-06

Defect description

E-One Incorporated (E-One) is recalling certain model year 2015-2016 Cyclone II, Quest II and Typhoon emergency vehicles manufactured May 1, 2015, to March 31, 2016, equipped with pumps to provide pressurized water to aid in fighting fires. These pumps have 6" intake strainers that may have been improperly soldered during production and, as a result, the strainers may come apart during use, allowing parts of the strainer and debris to enter the pump, possibly damaging the pump.

Safety risk

If the strainer and/or debris enters the pump, and the operator is forced to shut down the pump, reducing firefighting effectiveness, there could be an increased risk of injury.

Manufacturer remedy

E-One will notify owners to check the strainer for missing solder at the joints. Any strainers missing solder will be replaced, free of charge. The recall began on June 6, 2016. Owners may contact E-One customer service at 1-352-861-3612 or Hale customer service at 1-800-533-3569.

Notes

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.

Scope of coverage

6 model years across 3 models.

ModelYears on record
E-ONE Cyclone II2016 2015
E-ONE Quest II2016 2015
E-ONE Typhoon2016 2015

Safety recall repairs are provided free of charge by franchised dealers, regardless of vehicle age or mileage. This page displays aggregated data for the model year. To check recall status for a specific vehicle, search its VIN at nhtsa.gov.