Model year record

2019 CRESTLINE COACH CCL150 Type I

1 recall campaign on file for this model year. No owner complaints on file.

Recalls

Recall campaignNHTSA 21V003000

Seat belts: critical fasteners

Component
Seat belts: critical fasteners
Manufacturer
Braun Ambulances
Vehicles affected
61
Reported to NHTSA
2021-01-08
Owners notified
2021-03-01

Defect description

Braun Ambulances (Braun) is recalling certain 2019 and 2021 Crestline CCL150 Type III E-Series and 2019-2020 Crestline CCL150 Type I F-Series and CCL150 Type III G-Series ambulances. Two of the eight fastening points of the seat belt system installed in the ambulance patient compartment side-facing CPR seating position on the street-side of the vehicle may be defective. Two of the threaded inserts used for the rearward retractor and shoulder belt D-ring are installed too close to a mounting flange resulting in improper crimping of the threaded insert.

Safety risk

The improper crimping may result in partial or complete loss of effectiveness of the seat belt harness, increasing the risk of injury to the occupant in that seated position, in the event of a crash.

Manufacturer remedy

Braun will notify owners and dealers will inspect both seat belt anchor points and if no defect exists, no further action will be required. If the inspection shows the defect exists on one or both seat belt anchor points, your dealer will replace the defective insert(s) with nut plate(s) during the inspection, free of charge. The recall began on March 1, 2021. Owners may contact Braun Ambulances customer service at 1-877-344-9990.

Owner complaints

A complaint is one person's report to a federal agency. It is not a finding.

No complaints recorded for this model year.

Safety recall repairs are provided free of charge by franchised dealers, regardless of vehicle age or mileage. This page displays aggregated data for the model year. To check recall status for a specific vehicle, search its VIN at nhtsa.gov.