Model year record

1991 ELDORADO Transmark

1 recall campaign on file for this model year. No owner complaints on file.

Recalls

Recall campaignNHTSA 00V101000

Fuel system, other: delivery: hoses, lines/piping, and fittings

Component
Fuel system, other: delivery: hoses, lines/piping, and fittings
Manufacturer
ELDORADO NATIONAL
Vehicles affected
173
Reported to NHTSA
2000-04-07
Owners notified
2000-04-10

Defect description

VEHICLE DESCRIPTION: REAR ENGINE BUSES. THESE BUSES ARE POWERED BY A CNG ENGINE AND COPPER TUBING WAS USED AS VENT LINES.

Safety risk

THE COPPER TUBING IS UNABLE TO CONTAIN THE CNG VENTING IN THE ENGINE COMPARTMENT.

Manufacturer remedy

DEALERS WILL REPLACE THE 3/8" COPPER VENT LINE FROM THE LOWER REAR MANIFOLD TO THE ROOF WITH 1/2" STAINLESS STEEL TUBING.

Owner complaints

A complaint is one person's report to a federal agency. It is not a finding.

No complaints recorded for this model year.

Safety recall repairs are provided free of charge by franchised dealers, regardless of vehicle age or mileage. This page displays aggregated data for the model year. To check recall status for a specific vehicle, search its VIN at nhtsa.gov.