Model year record

1981 Ford F250

5 recall campaigns on file for this model year. 1 owner complaint on file.

Recalls

Recall campaignNHTSA 82V024000

Equipment: mechanical: carrier/rack

Component
Equipment: mechanical: carrier/rack
Manufacturer
FORD MOTOR COMPANY
Vehicles affected
12,500
Reported to NHTSA
1982-03-15
Owners notified
1982-05-10

Defect description

THE REINFORCEMENT FOR THE IN-BOX SPARE TIRE CARRIER MAY HAVE BEEN ATTACHED USING INCORRECT HEX HEAD BOLTS. IF THE CARRIER AND REINFORCEMENT ATTACHING BOLTS ARE INCORRECT, THE POTENTIAL EXISTS FOR THE TIRE SIDEWALL TO BE DAMAGED OR WEAKENED BY EXTENDED CONTACT WITH THE SHARP EDGES OF THE BOLT HEADS.

Manufacturer remedy

DEALER WILL REPLACE BOLTS AND ANY DAMAGED SPARE TIRES AT NO COST TO OWNER.

Recall campaignNHTSA 81V121000

Wheels: multi piece

Component
Wheels: multi piece
Manufacturer
FORD MOTOR COMPANY
Vehicles affected
16,500
Reported to NHTSA
1981-10-06
Owners notified
1981-11-09

Defect description

THE OWNER"S GUIDE MAY CONTAIN AN ERROR IN THE WHEEL LUG NUT TORQUE SPECIFICATION CHART. INCORRECT INFORMATION COULD RESULT IN IMPROPER TORQUE OF THE LUG NUTS DURING WHEEL REPLACEMENT. LUG NUTS COULD COME LOOSE DURING VEHICLE OPERATION.

Manufacturer remedy

AN ADHESIVE-BACKED, REVISED PAGE WILL BE SUPPLIED TO OWNERS FOR INSERTION IN THE OWNER"S GUIDE. IN ADDITION, DEALERS WILL PROVIDE TORQUE VERIFICATION, IF ONE OR MORE WHEELS HAVE BEEN SERVICED, AT NO COST TO OWNERS.

Recall campaignNHTSA 81V061000

Structure

Component
Structure
Manufacturer
FORD MOTOR COMPANY
Vehicles affected
130
Reported to NHTSA
1981-05-21
Owners notified
1981-06-18

Defect description

THE INVOLVED TRUCKS WERE MANUFACTURED WITH A CERTAIN PORTION OF SPECIFIED FLOOR PAN INSULATION MATERIAL (BENEATH THE RIGHT FRONT PASSENGER SEAT) OMITTED. BECAUSE OF THIS OMISSION, A SECTION OF THE SHEET METAL FLOOR PAN WAS LEFT EXPOSED OVER THE EXHAUST SYSTEM IN AN AREA OF POSSIBLE PASSENGER CONTACT.

Manufacturer remedy

THE DEALER WILL INSTALL A REVISED DESIGN FLOORPAN INSULATOR PAD AT NO CHARGE TO OWNER.

Recall campaignNHTSA 81V023000

Fuel system, gasoline: storage: tank assembly: mounting

Component
Fuel system, gasoline: storage: tank assembly: mounting
Manufacturer
FORD MOTOR COMPANY
Vehicles affected
26
Reported to NHTSA
1981-02-13
Owners notified
1981-04-15

Defect description

CERTAIN VEHICLES MAY HAVE BEEN ASSEMBLED WITHOUT THE SPECIFIED FUEL TANK SHIELD WHICH PREVENTS DIRECT CONTACT BETWEEN THE FUEL TANK AND DRIVELINE COMPONENTS. DURING A 30 MPH FRONTAL BARRIER IMPACT TEST, AS SPECIFIED IN FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY", FUEL LEAKAGE MAY OCCUR.

Manufacturer remedy

VEHICLES WILL HAVE THE EXISTING SEPARATE SKID PLATE OR FUEL TANK SHIELD REMOVED (WHICHEVER WAS INSTALLED ON VEHICLE). A SPECIAL COMBINATION SKID PLATE/FUEL TANK SHIELD ASSEMBLY WILL BE INSTALLED IN ITS PLACE FREE OF CHARGE.

Recall campaignNHTSA 80V145000

Fuel system, gasoline: storage: tank assembly: mounting

Component
Fuel system, gasoline: storage: tank assembly: mounting
Manufacturer
FORD MOTOR COMPANY
Vehicles affected
6,260
Reported to NHTSA
1980-11-10
Owners notified
1980-12-01

Defect description

DURING A CHANGE IN ASSEMBLY PROCEDURES, CERTAIN OF THE MID-SHIP FUEL TANK STRAPS MAY HAVE BEEN IMPROPERLY INSTALLED OR MISLOCATED. AS A RESULT, THEY FAIL TO CONFORM TO FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". IN THE EVENT OF A COLLISION, EXCESSIVE FUEL SPILLAGE MAY OCCUR.

Manufacturer remedy

DEALER WILL INSPECT AND, IF NECESSARY, RELOCATE FUEL TANK STRAPS WITHOUT CHARGE TO OWNER.

Owner complaints

A complaint is one person's report to a federal agency. It is not a finding.

ComponentComplaintsMedian mileage
Power train: automatic transmission1

Safety recall repairs are provided free of charge by franchised dealers, regardless of vehicle age or mileage. This page displays aggregated data for the model year. To check recall status for a specific vehicle, search its VIN at nhtsa.gov.