Electrical system: wiring: fuses and circuit breakers
- Component
- Electrical system: wiring: fuses and circuit breakers
- Manufacturer
- HOLIDAY RAMBLER CORP.
- Vehicles affected
- 138
- Reported to NHTSA
- 1994-12-29
- Owners notified
- 1995-03-03
Defect description
THE 12 VOLT BUSS BAR AND TERMINAL CONNECTOR LUG POST WERE INSTALLED WITHOUT A PROTECTIVE COVER. THESE COMPONENTS ARE SUSCEPTIBLE TO POTENTIAL SHORTING UPON CONTACT BY ANY TYPE OF METAL FOREIGN OBJECT.
Safety risk
THIS CONDITION CAN CAUSE A SHORT CIRCUIT AND A POTENTIALFIRE HAZARD.
Manufacturer remedy
DEALERS WILL INSTALL A PROTECTIVE SHIELD TO COVER THE ELECTRICAL COMPONENTS.