Model year record

2015 HORTON AMBULANCE 603

2 recall campaigns on file for this model year. No owner complaints on file.

Recalls

Recall campaignNHTSA 16V625000

Equipment: appliance: air conditioner

Component
Equipment: appliance: air conditioner
Manufacturer
Halcore Group, Inc.
Vehicles affected
351
Reported to NHTSA
2016-08-26
Owners notified
2016-10-26

Defect description

Halcore Group, Inc. (Halcore) is recalling certain model year 2013-2016 Horton ambulances, models 453, 457, 503, 553, 603, and 623, manufactured November 29, 2013, to March 1, 2016. The affected vehicles may have an improperly sealed Cool-Tech air-conditioning condenser controller wire harness that can allow water to enter the controller housing.

Safety risk

If water gets into the controller housing, the controller may short circuit, increasing the risk of an electrical fire.

Manufacturer remedy

Halcore will notify owners, and dealers will replace the Cool-Tech condenser fan controller assembly, free of charge. Halcore issued an interim notification to owners on September 9, 2016. The recall began on October 26, 2016. Owners may contact Horton customer service at 1-614-317-9856, or by email at [email protected]

Recall campaignNHTSA 15V828000

Electrical system

Component
Electrical system
Manufacturer
Halcore Group, Inc.
Vehicles affected
18
Reported to NHTSA
2015-12-09
Owners notified
2016-01-04

Defect description

Halcore Group, Inc. (Halcore) is recalling certain model year 2015 Horton 623, 603, 503, 553 and 453 ambulances manufactured October 1, 2015, to November 16, 2015 and equipped with the i4G system for controlling the ambulance body electrics. Due to a circuit board component being installed incorrectly, the ambulance body may have electrical system failure of the interior and exterior lights, as well as other life saving electrical equipment such as the oxygen system.

Safety risk

Failure of ambulance body electrics can hinder emergency response and/or rescue efforts, increasing the risk of injury to ambulance patients.

Manufacturer remedy

Halcore will notify owners, and Horton will replace the affected electrical component, free of charge. The recall began on January 4, 2016. Owners may contact Horton customer service at 1-800-282-5113.

Owner complaints

A complaint is one person's report to a federal agency. It is not a finding.

No complaints recorded for this model year.

Safety recall repairs are provided free of charge by franchised dealers, regardless of vehicle age or mileage. This page displays aggregated data for the model year. To check recall status for a specific vehicle, search its VIN at nhtsa.gov.