Model year record

2019 HORTON Type III

5 recall campaigns on file for this model year. No owner complaints on file.

Recalls

Recall campaignNHTSA 20V291000

Service brakes

Component
Service brakes
Manufacturer
Halcore Group, Inc.
Vehicles affected
17
Reported to NHTSA
2020-05-20
Owners notified
2020-06-05

Defect description

Halcore Group, Inc. (Halcore) is recalling certain 2018-2020 Horton Emergency Vehicles (HEV) Type I & Type III ambulances built on a Ram 4500 or 5500 chassis and equipped with Compressible Liquid Adaptive Suspension Systems (C.L.A.S.S.), part numbers DS135RS3A, DS135RS3AF, DS135RS3-DM. The rear brake caliper flexible line may have been routed so that it contacts a suspension component, possibly causing excessive wear and a loss of rear brakes. The affected system component is the rear brake caliper flexible line which may be causing brake caliper to wear due to contact suspension components.

Safety risk

A worn rear brake caliper flexible line may cause brake fluid leakage which may result in a partial or complete loss of the rear brakes, increasing the risk of a crash.

Manufacturer remedy

Halcore will notify owners, and dealers will inspect the rear brake caliper flexible lines for wear and install a kit to modify the rear brake caliper flexible line mounting, and if necessary, a kit to replace worn brake lines, free of charge. This recall began June 5, 2020. Owners may contact Halcore customer service at 1-800-447-0343.

Recall campaignNHTSA 20V128000

Equipment: electrical

Component
Equipment: electrical
Manufacturer
Halcore Group, Inc.
Vehicles affected
18
Reported to NHTSA
2020-03-04
Owners notified
2020-03-10

Defect description

Halcore Group, Inc. (Halcore) is recalling certain 2016-2019 Horton Emergency Vehicles Type I and Type III ambulances. The A/C input power cord for the Sensata inverter may be undersized for certain inverter applications, possibly resulting in an electrical short circuit.

Safety risk

An electrical short circuit increases the risk of a fire or a shock hazard.

Manufacturer remedy

Halcore has notified owners, instructing them to contact Sensata for a replacement power cord, free of charge. The recall began March 10, 2020. Owners may contact Halcore customer service at 1-800-447-0343.

Recall campaignNHTSA 19V742000

Equipment

Component
Equipment
Manufacturer
Halcore Group, Inc.
Vehicles affected
11
Reported to NHTSA
2019-10-17
Owners notified
2019-11-07

Defect description

Halcore Group, Inc. (Halcore) is recalling certain 2018-2019 Horton Type I & Type III ambulances. The D-cylinder oxygen tank bracket may loosen, allowing the oxygen tank to separate and become airborne in the event of a crash.

Safety risk

An unsecured oxygen tank may strike ambulance occupants and increasing the risk of injury in the event of a crash.

Manufacturer remedy

Halcore will notify owners, and Ziamatic will refund the purchase price paid, or provide replacement bracket assemblies, free of charge. The recall began November 7, 2019. Owners may contact Halcore customer service at 1-800-447-0343.

Recall campaignNHTSA 19V608000

Air bags

Component
Air bags
Manufacturer
Halcore Group, Inc.
Vehicles affected
80
Reported to NHTSA
2019-08-19
Owners notified
2019-09-20

Defect description

Halcore Group, Inc. (Halcore) is recalling certain 2018-2020 Horton Type I and Type III Emergency vehicles. Due to improper manufacturing, the cushion of the Inflatable Head Cushion (IHC) and Knee Air Bag (KAB) may detach during a deployment event and not inflate.

Safety risk

In the event of a crash, if the cushions do not inflate properly, they may not provide the intended protection to the occupant, increasing the risk of injury.

Manufacturer remedy

Halcore will notify owners and dealers will install replacement air bags when they become available, free of charge. Halcore issued owners an interim notification on September 6, 2019. The recall began September 20, 2019. Owners may contact Halcore customer service at 1-800-447-0343.

Recall campaignNHTSA 19V281000

Back over prevention: sensing system: camera

Component
Back over prevention: sensing system: camera
Manufacturer
Halcore Group, Inc.
Vehicles affected
49
Reported to NHTSA
2019-04-09
Owners notified
2019-06-13

Defect description

Halcore Group, Inc. (Halcore) is recalling certain 2016-2019 Horton Type I and Type III ambulances equipped with ASA Electronics back-up camera displays. The displays may revert back to the factory default settings which may cause the camera image to be reversed.

Safety risk

The driver may inadvertently turn the wrong direction to avoid an object behind the vehicle, increasing the risk of a crash.

Manufacturer remedy

Horton will notify owners and dealers will add a harness relay capacitor module to prevent the image from reversing, free of charge. The recall began June 13, 2019. Owners may contact ASA customer service at 1-800-384-4400 or Halcore at 1-800-447-0343.

Owner complaints

A complaint is one person's report to a federal agency. It is not a finding.

No complaints recorded for this model year.

Safety recall repairs are provided free of charge by franchised dealers, regardless of vehicle age or mileage. This page displays aggregated data for the model year. To check recall status for a specific vehicle, search its VIN at nhtsa.gov.